Non-Destructive Method

Ultrasonic Testing Acceptance Criteria: Codes, Limits and Reject Levels

Updated

Ultrasonic Testing Acceptance Criteria

Ultrasonic testing acceptance criteria are the limits, set by the construction code rather than the examination standard, that decide whether a UT indication is accepted or repaired. AWS D1.1 classes indications A to D from d = a − b − c; ASME Section VIII and B31.3 reject "other" indications only when amplitude exceeds the reference level and length exceeds a thickness limit.

The same indication can therefore pass under one code and fail under another. This guide covers the codes a US buyer usually meets: AWS D1.1 for structural steel, ASME Section VIII and B31.3 for vessels and process piping, API 1104 for pipelines, and 49 CFR 213.113 plus the owner's specification for rail.

Contents: Examination vs acceptance · Which code applies · AWS D1.1 · ASME VIII · B31.3 · API 1104 · Rail · Over the limit · Limits · FAQ

About the numbers: AWS D1.1, ASME, API and ISO standards are paywalled. The limits below come from the publishers' public pages and from secondary sources that agree with one another. Check every value against the edition named in your contract before accepting or rejecting a weld.

What is the difference between an examination standard and ultrasonic testing acceptance criteria?

An examination standard says how to perform UT; acceptance criteria say what result is acceptable. A technician can locate and size an indication perfectly and still need a separate document to decide whether it passes.

The work runs in this order: written procedure → calibration → examination → indication → evaluation → acceptance decision. The documents split along the same line.

DocumentWhat it doesSets acceptance limits?
ASME BPVC Section V, Article 4UT method for welds: equipment, calibration, scanning, recordingNo. It defers to the referencing code
ISO 16810:2024General principles of industrial UTNo. Its scope excludes acceptance criteria and the extent of testing
ASTM E164-24Contact UT of weldmentsNo. Limits must be agreed between manufacturer and purchaser
ASTM E2700-26Contact UT of welds with phased arraysNo. It is a practice, not an acceptance standard
AWS D1.1/D1.1M:2025, Clause 8Structural steel weldsYes: Classes A to D
ASME Section VIII, Division 1Pressure vesselsYes, when it calls for UT of welds
ASME B31.3Process pipingYes
API Std 1104Pipeline girth weldsYes
ISO 11666:2018Full-penetration welds in ferritic steelYes: acceptance levels 2 and 3
49 CFR 213.113Defective rails in trackRemedial action by defect type and size

ASTM puts the point plainly in E164-24: when UT is the basis of weld acceptance, "there should be agreement between the manufacturer and the purchaser" on the reference standards and limits (ASTM E164-24).

ISO 11666:2018 is the European-style example of a true acceptance standard. It sets acceptance levels 2 and 3 for welds 8 to 100 mm thick, tied to ISO 5817 quality levels B and C, for testing performed to ISO 17640. US projects rarely invoke it unless the client is working to EN or ISO practice.

Key takeaway: identify the construction code first. A UT method standard will never give you a reject number.

Which code sets the acceptance criteria for your job?

The component and the contract decide the code, and the code decides how an indication is judged. The table below shows the rating logic each code uses.

ComponentUsual codeHow an indication is judgedQualifier you must state
Structural steel building or plant weldsAWS D1.1Rating d = a − b − c, then class A–D and a length limitStatic or cyclic loading; weld thickness; probe angle
Pressure vessel weldsASME Section VIII, Div. 1Flaw type first, then amplitude above reference and lengthThickness band; whether UT replaces RT
Process piping weldsASME B31.3Linear indication: amplitude above reference and lengthTw of the thinner component; fluid service
Gas and liquid pipeline girth weldsAPI 1104Indication type (linear surface, linear buried, volumetric) and aggregate lengthEdition (21st is the one in 49 CFR)
BridgesAWS D1.5D1.5's own UT tablesFracture-critical members
Rail in track49 CFR 213.113 plus owner's specDefect type, then percent of head area or lengthTrack class; who is the designated person
Railcars and locomotivesAWS D15.1/D15.1M:2025D15.1 and the car builder's specNot a rail-in-track standard

If a project specification is stricter than the code, the specification governs. The code is the floor.

How does AWS D1.1 rate and accept a UT indication?

AWS D1.1 rates each indication with d = a − b − c and looks the rating up in a static or cyclic table by weld thickness and probe angle. The result is Class A, B, C or D, and each class has its own length rule. This is a summary; our full guide to AWS D1.1 acceptance criteria covers the visual limits, table numbering and personnel rules in depth.

TermMeaning
aIndication level: dB needed to bring the flaw echo to the reference line
bReference level: dB needed to bring the 0.060 in. (1.5 mm) side-drilled hole echo to the same line
cAttenuation factor: 2 × (sound path in inches − 1) dB
dIndication rating: a − b − c

The sign convention trips people up. A lower, more negative rating means a stronger reflector, because the flaw needed less gain than the reference hole. Class A, the most severe class, therefore sits at the low end of each table.

ClassStatically loadedCyclically loaded
A (large)Reject at any lengthReject at any length
B (medium)Reject if longer than 3/4 in.Reject if longer than 3/4 in.
C (small)Reject if longer than 2 in.Reject if longer than 2 in. in the middle half of the thickness, or 3/4 in. in the top or bottom quarter
D (minor)Accept at any lengthAccept at any length

Thickness scope: the D1.1 Part F procedure covers groove welds from 5/16 in. to 8 in. (8 to 200 mm). Thinner or thicker welds need a procedure qualified under the code's alternative provisions. D1.1 also doesn't require UT on its own; the contract, AISC 360 or AISC 341 does.

Worked example: one rating, two loading cases

Setup. A 3/4 in. CJP butt weld is scanned with a 70° probe. The reference level from the side-drilled hole is b = 65 dB. An indication peaks at the reference line at a = 79 dB, with a sound path of 3.0 in.

  • Attenuation: c = 2 × (3.0 − 1) = 4 dB
  • Rating: d = 79 − 65 − 4 = +10
  • Location check: 3.0 in. × cos 70° = 1.03 in. of depth travel, which is past the 0.75 in. back wall, so the reflector is on the second leg at about 2 × 0.75 − 1.03 = 0.47 in. below the scanning surface
  • Surface distance: 3.0 in. × sin 70° = 2.82 in. from the probe exit point

Statically loaded. In the 5/16 to 3/4 in. row at 70°, Class A is +5 and lower and Class B is +6, and published summaries put Class C at +7 and Class D at +8 and higher. So +10 is Class D: accept at any length.

Cyclically loaded. Secondary reproductions of the cyclic table place Class A at +10 and lower in the same row. The same +10 is Class A: reject at any length.

Nothing about the flaw changed; only the loading column did. A 2 dB error in c would also move this indication across a class boundary, which is why the report must record a, b, c and d for every indication. A crack identified by any means is rejected whatever its rating.

Calibration rules that make the rating valid

A rating is only as good as the calibration behind it. Secondary summaries of D1.1 give these requirements:

RequirementSummary value (confirm in your edition)
InstrumentPulse-echo, for search units of 1 to 6 MHz, A-scan display
Gain controlCalibrated in 1 or 2 dB steps over at least 60 dB
RecalibrationOn a change of operator, at 30 minutes maximum, and whenever the circuitry is disturbed (transducer, cable, battery or power change)
Reference reflector0.060 in. (1.5 mm) side-drilled hole in an IIW-type block

A "recheck every two hours" is not the D1.1 interval. See our guides to UT formulas and DAC curves for the sizing and amplitude basics.

Key takeaway: always say "static or cyclic" and the thickness before quoting a D1.1 class.

What are the ASME Section VIII ultrasonic acceptance criteria?

Under ASME Section VIII, Division 1, Mandatory Appendix 12, indications above 20% of the reference level are investigated; cracks, lack of fusion and incomplete penetration are rejected at any length; other imperfections are rejected only if their amplitude exceeds the reference level and their length exceeds a thickness-based limit. Section V, Article 4 sets how the examination is done; Appendix 12 sets acceptance.

The "and" is the part most summaries drop. A long, low-amplitude indication that is not a crack, lack of fusion or incomplete penetration is not rejectable on length alone.

Weld thickness tMaximum length of an "other" imperfection above reference level
Up to 3/4 in. (19 mm)1/4 in. (6 mm)
3/4 in. to 2¼ in. (19 to 57 mm)t/3
Over 2¼ in. (57 mm)3/4 in. (19 mm)

Source: Appendix 12 wording as reproduced in UT procedures and NDT references. Confirm against the 2025 edition of Section VIII, Division 1, or the edition on your contract.

Worked example: four indications in a 1½ in. vessel seam

For t = 1.5 in., the length limit is t/3 = 0.50 in. Each indication below exceeded 20% of the reference level, so each was investigated.

IndicationCharacterized asAmplitude vs referenceLengthResult
1Slag140%0.40 in.Accept: above reference, but under 0.50 in.
2Slag line60%0.70 in.Accept: over 0.50 in., but not above reference
3Slag line130%0.70 in.Reject: above reference and over 0.50 in.
4Lack of fusion50%0.20 in.Reject: lack of fusion at any length

Indication 2 is the one a careless evaluation rejects. Indication 4 is the one an amplitude-only evaluation accepts.

Watch the trigger for UT. Appendix 12 applies where Division 1 calls for UT of welds under that appendix. When UT is used in place of radiography, Division 1 points to different, more detailed acceptance rules (workmanship or fracture-mechanics based) under UW-51 in recent editions. Our guide to ASME weld ultrasonic inspection covers the vessel side in more depth.

How does ASME B31.3 accept UT indications?

ASME B31.3 paragraph 344.6.2 rejects a linear-type discontinuity when its amplitude exceeds the reference level and its length exceeds a limit based on Tw, the nominal wall thickness of the thinner component in the butt weld. The bands match Section VIII.

TwLength limit
Up to 3/4 in. (19 mm)1/4 in. (6 mm)
Over 3/4 in. to 2¼ in. (19 to 57 mm)Tw/3
Over 2¼ in. (57 mm)3/4 in. (19 mm)

The examination itself follows Section V, Article 4, with B31.3's own allowances for calibration blocks. B31.3 also sets how much to examine, which differs by fluid service. Published summaries put normal fluid service at no less than 5% random radiographic or ultrasonic examination of circumferential butt welds, with heavier examination for severe cyclic conditions; read paragraph 341.4 in your edition for the exact extent.

Two points cause confusion. First, requirements for examining pipe and tubing as product forms are material requirements, not weld acceptance criteria, so keep them separate. Second, ASME B31.1 (power piping) has its own UT acceptance paragraph. Some summaries say it mirrors Section VIII, but read B31.1 itself rather than assume it.

Key takeaway: in both Section VIII and B31.3, "other" indications need to fail on amplitude and length together.

What are the API 1104 UT acceptance standards?

API 1104 judges pipeline girth weld UT indications by type and aggregate length, not by a single amplitude-and-length formula, and it rejects cracks outright. Secondary summaries of the UT acceptance standards give these limits for linear surface, linear buried and volumetric root indications:

Indication typeRejected when
CrackAny crack
Linear surface (LS), open to the OD or IDAggregate length over 1 in. (25 mm) in any continuous 12 in. (300 mm) of weld, or over 8% of the weld length
Linear buried (LB)Aggregate length over 2 in. (50 mm) in any continuous 12 in. of weld, or over 8% of the weld length
Volumetric root (VR)Maximum dimension over 1/4 in. (6 mm), or aggregate over 1/2 in. (13 mm) in any continuous 12 in.
Volumetric cluster and individualSize limits in the edition's UT acceptance section

Edition matters here more than anywhere. API's current edition is the 22nd, but 49 CFR 192.7 incorporates the 21st edition (September 2013) with its errata and addenda, for welder and procedure qualification and for 192.241(c) weld acceptance (49 CFR 192.7 on eCFR). On a PHMSA-regulated gas line, the regulatory floor is the 21st edition unless the operator's procedures adopt something stricter.

API 1104 also has an annex that allows alternative acceptance standards based on fracture mechanics, used with automated UT on some mainline projects. That route needs a qualified procedure and the operator's approval; it is not a field choice.

What are the acceptance criteria for rail ultrasonic testing?

For rail in track, there is no accept/reject class table. FRA's 49 CFR 213.113 names the defect types and sets a remedial action by defect size, and the track owner's specification and AREMA recommended practice add the rest. The regulation puts the decision with a qualified person:

"When an owner of track learns that a rail in the track contains any of the defects listed in the table contained in paragraph (c) of this section, a person designated under § 213.7 shall determine whether the track may continue in use." (49 CFR 213.113(a))

The remedial action table sizes transverse defects as a percentage of the rail head cross-section weakened, and longitudinal defects by length in inches.

Defect (transverse group)Head area weakenedRemedial action note
Transverse fissure, detail fracture, engine burn fracture, defective weld5% to under 25%C
Same25% to under 60%D
Same60% to under 100%A2, or E and H
Same100%A, or E and H
Compound fissure5% to under 70%B
Compound fissure70% to under 100%A2
Compound fissure100%A

Source: the remedial action table as revised by FRA's 2014 Improving Rail Integrity final rule (79 FR 4234, January 24, 2014). Check the current table on eCFR before relying on a cell.

What the notes require, in short:

NoteRequirement (summary)
AA designated person visually supervises each movement over the rail
A2A designated person inspects visually; trains may then run at 10 mph for up to 24 hours before the next inspection or repair
BSpeed set by a designated person with at least one year of track supervisory experience, no more than 30 mph
CJoint bars through the outermost holes within 10 days; 10 mph if not applied by then
DJoint bars through the outermost holes within 7 days; 10 mph if not applied by then
E and HJoint bars bolted per 213.121(d) and (e), then 50 mph or the class limit, whichever is lower

Horizontal and vertical split heads, split webs, piped rail, head-web separations and bolt hole cracks are sized by length, with tighter actions as they grow past 1 in., 1½ in. or 4 in. depending on the type. A defective weld under 213.113 is a field or plant weld with discontinuities over 5% of the rail head area individually or 10% in aggregate, oriented in or near the transverse plane.

Where the owner's spec and AREMA fit

FRA sets the minimum; the owner sets the acceptance standard for new work. A transit agency's thermite or flash-butt weld specification typically names the UT procedure, the reference reflector and the reject level for new welds before they go into service, often citing AREMA's Manual for Railway Engineering Chapter 4 (Rail). AREMA publishes recommended practices, not regulations, so its material governs only when the owner's specification adopts it. AWS D15.1 is a different document: it covers welding of railcars and locomotives, not rail in track.

For the field side of rail weld UT, see our guides to aluminothermic weld inspection, flash-butt weld inspection and FRA defect codes.

Key takeaway: in rail, detection is the UT operator's job; disposition under 213.113 belongs to the owner's designated person.

What happens when an indication exceeds the acceptance limit?

An over-limit indication is confirmed before it is rejected, and the disposition is documented. A practical sequence:

  1. Rescan to confirm the indication from more than one direction or angle.
  2. Verify its location, depth and length, and rule out geometry such as root reinforcement or a backing bar.
  3. Recheck calibration if the procedure or code requires it.
  4. Confirm the governing code, edition and loading or service category.
  5. Compare the result with the applicable limit and record a, b, c and d (D1.1) or amplitude and length (ASME, API).
  6. Report the indication and the disposition to the inspector or engineer responsible for acceptance.
  7. Repair, or apply an engineering disposition where the code allows one.
  8. Re-examine the repaired area to the same procedure.

This reduces both unnecessary repairs and missed defects. Under D1.1, the CWI or engineer decides acceptance; under 213.113, the owner's designated person decides whether track stays in service.

How do PAUT and TOFD change the acceptance criteria?

They change how indications are found and sized, not the acceptance limits. ASTM E2700-26 covers phased array UT of welds and notes that sizing needs suitable procedures. D1.1 has a PAUT annex with its own procedure requirements. API 1104's fracture-mechanics annex is the main case where a different technique comes with different acceptance criteria, and only because the annex says so. See our guides to phased array ultrasonic testing and PAUT vs TOFD for rail welds.

What ultrasonic testing acceptance criteria don't cover

Acceptance tables assume the procedure fits the part. When it doesn't, the numbers stop meaning what they say.

SituationWhy the tables may not apply or may not be enough
Thin welds below 5/16 in. (D1.1)Outside the Part F scope; near-surface resolution suffers and a qualified alternative procedure is needed
Complex tubular T-, Y- and K-connectionsNeed procedures written for the geometry
Austenitic stainless and coarse-grained weldsBeam skew and scatter make amplitude-based rules unreliable
Smooth planar flaws at a poor angle to the beamLow amplitude; can rate as Class D or fall below the reference level
Thick D1.1 weldsThe 2 dB/in. attenuation model can be about 6 dB off at 60° and 70° near 6 in. of sound path (Holloway, CINDE Journal, 2017)
Rail with shelling or head checksSurface damage can mask internal defects from the probe
Thermite welds in trackTest cars cover little of the rail base, so field welds need hand UT
A project spec stricter than the codeThe spec governs

The common mistakes follow the same pattern:

MistakeCorrect practice
One reject number for every jobIdentify the code, edition and qualifier first
Treating ASME Section V or ISO 16810 as acceptance criteriaThey are method standards
Rejecting an ASME "other" indication on length aloneAmplitude above reference and length over the limit
Reading a D1.1 positive rating as "worse"Lower ratings are stronger reflectors
Quoting a D1.1 class without the loading columnState static or cyclic
Using the 22nd edition of API 1104 for a regulated gas line by default49 CFR 192.7 incorporates the 21st
Calling the UT operator's call on rail a "reject"213.113 disposition belongs to the designated person

How EMA Industries applies this

EMA Industries performs AWS D1.1 structural weld UT, MT and PT, ultrasonic rail flaw testing and rail weld inspection, and NDT Level III services, including procedure writing and WPS/PQR support. We're based in Southern California and mobilize nationwide. Before scanning, the governing code, edition and loading or service category should be confirmed from the contract, and the report should record the reference level, rating, class or amplitude, and length of every indication evaluated, so the person who decides acceptance can see the basis for the call. See our ultrasonic examination services or contact EMA Industries to scope an inspection.

Related reading: AWS D1.1 acceptance criteria · Weld defect types · Lack of fusion in welds · SNT-TC-1A requirements · 49 CFR 213.237 rail flaw inspection

Frequently asked questions

What are the ASME acceptance criteria for ultrasonic testing?

They come from the construction code, not Section V. In Section VIII, Division 1, Appendix 12, indications above 20% of the reference level are investigated, cracks, lack of fusion and incomplete penetration are rejected at any length, and other imperfections are rejected only when amplitude exceeds the reference level and length exceeds 1/4 in., t/3 or 3/4 in. depending on thickness. B31.3 uses the same length bands for linear indications.

What is an example of acceptance criteria?

AWS D1.1's Class B rule is a typical one: an indication whose rating falls in the Class B band for that thickness and probe angle is rejected if it is longer than 3/4 in. In rail, the equivalent is the 213.113 rule that a transverse fissure weakening 25% to under 60% of the head area requires joint bars within 7 days.

Who prepares acceptance criteria?

Code committees write them (AWS, ASME, API), regulators set them for regulated assets (FRA for rail in track, PHMSA through its incorporation of API 1104), and the engineer or owner adds project-specific limits in the contract. Where no code applies, an NDT Level III typically drafts criteria in a written procedure for the owner to approve.

What is the minimum thickness for ultrasonic weld testing under AWS D1.1?

The D1.1 Part F procedure starts at 5/16 in. (8 mm) and runs to 8 in. (200 mm). Thinner welds can still be tested ultrasonically, but only with a procedure qualified for that thickness, not by applying the Part F tables directly.

What is the difference between accuracy and acceptance criteria?

Accuracy describes how closely a measurement matches a flaw's real position and size, and it depends on calibration against known reflectors. Acceptance criteria are the limits the measured result is judged against. An accurate measurement compared with the wrong code still produces the wrong decision.

Sources

← All articles